XrayTech Maxus

Cost: On request
Description
Specifications

Universal XrayTech Maxus X-ray television system designed for monitoring a wide range of control objects made of various materials.

Radiation Protection Chamber

The protective chamber is made of steel and lead in accordance with international and Russian standards for the protection of personnel from X-rays and is designed to work with X-ray machines with a voltage of up to 450 kV. It is equipped with an automatic sliding door, a lighting system, a labyrinth window for cables and connection of supply and exhaust ventilation, locking and alarm systems.

Manipulator

The system is equipped with a specialized manipulator, which has 7 degrees of freedom:

  • vertical movement of the X-ray tube
  • rotation of the X-ray tube
  • vertical movement of the detector
  • rotation of the detector
  • horizontal movement of the object table in two directions
  • rotation of the object table relative to the vertical axis

For convenience and to increase the speed of control, the object table can be equipped with an additional footrest and can be extended beyond the protective chamber.

X-ray machine

X-ray devices of cable type with anode voltages up to 450 kV are used as a source of X-ray radiation. To improve the quality of the images obtained, an adjustable aperture is used.

X-ray detector

As an X-ray detector, radiation-resistant high-resolution flat-panel detectors with the area of the working area necessary to solve the control tasks are used.

Control

The control of the detector manipulator, the X-ray tube manipulator and the object table is carried out remotely from the workplace of the operator of the X-ray television complex using a video surveillance system. On the ergonomic control panel there are joysticks for moving manipulators, changing the operating modes of the X-ray machine and other controls.

In the presence of an optional automation system of the complex, automated control of the same type of products is possible according to a certain preset program.

The image enhancement system provides the ability to process the resulting images. Optionally, it is possible to retrofit the complex to obtain a three-dimensional image in the computed tomography mode.

Maxus -160 Maxus-225 Maxus -320 Maxus -450
Maximum high voltage 160kV 225kV 320kV 450kV
Generator output power 4500W 4500W 4500W 4500W
Type of X-ray machine Stationary, cable type
Maximum sample size (Øх D) 800 х 1500 mm
Diameter of the rotary table for products 820 mm
Product weight up to 350 kg
Vertical movement of the X-ray tube 1700 mm
Angle of inclination of the X-ray tube up to ±45°
Vertical movement of the detector 1550 mm
Detector tilt angle up to ±35°
Horizontal movement of the control object along 880 mm
Horizontal movement of the control object across 880 mm
Rotating the subject table n x 360º
Detector Many types of X-ray television detectors with different input window sizes and spatial resolution can be used as part of the system.