Radiation protection chamber EcoCAB 12x08x12
One of the main arguments when choosing this equipment is the lack of a stationary X-ray protection room. The EcoCAB radiation protection chamber ensures the radiation safety of personnel work when using an X-ray machine with an anode voltage of up to 250 kV.
The EcoCAB protective chamber has been designed in accordance with the current regulations in the field of x-ray inspection. All necessary documentation is provided with the equipment.
The structure of the protective chamber is made of steel and lead, equipped with automatic sliding doors for X-ray protection, a lighting system, a labyrinth window for entering the necessary cables and connecting the supply and exhaust ventilation.
The door of the protective chamber is equipped with interlocks that ensure the termination of X-ray generation when the door is opened, and also block the turning on of the X-ray machine when the door is open. Outside and inside the chamber, well-marked and easily accessible buttons for emergency shutdown of the X-ray machine are installed.
A light panel “X-ray translucence” and a radiation hazard sign are installed on the protective chamber. In addition, in the event of a malfunction of the blocking and alarm systems, a protective circuit has been implemented that does not allow turning on the X-ray machine.
As a source of X-ray radiation, it is possible to use an X-ray apparatus, both cable-type and portable.
It is possible to develop the design of the radiation protection chamber for the special conditions of the customer or the configuration of the existing equipment.
| Specifications | Value |
| Protective chamber design | steel-lead |
| Internal dimensions (L x W x H) | 1200 х 800 x 1200 mm |
| Radiation level at a distance of 10 cm from the camera surface | Max 1.0 µSv/h |
| Maximum voltage on the tube | Max 250 kV |
| Maximum tube power at maximum voltage | Max 4500W |
| Door | Sliding in X-ray protection design |
| Opening size (width x height) | 1180 х 1200 mm |