EcoImpulse EI-T

Cost: On request
Description
Specifications

The EcoImpulse line of portable X-ray machines uses the principle of explosive electron emission in an X-ray tube with a cold cathode.

The main argument when choosing this equipment is the budget solution of radiographic tasks in the field. To increase the mobility of the control, batteries are used as a power source for the X-ray machine.

The standard EcoImpulse kit includes the following components:

  • X-ray unit
  • high-voltage cable
  • portable X-ray control panel
  • cable network
  • case
  • battery 24V (optional)
  • remote control (optional)
  • housing diaphragm (optional)

It is possible to retrofit additional equipment on request.

Main features of EcoImpulse pulsed X-ray machines:

  • The possibility of both directional and panoramic transmission.
  • Short exposures — the only adjustable parameter of the device is the exposure time (voltage and current are unchanged).
  • To obtain high-quality contrast images, it is recommended to use a highly sensitive X-ray film with amplifying screens.
  • Application in areas with low intensity, since the maximum operating time of the device should not exceed 15 minutes per hour.
  • An autonomous source of X-ray radiation when using batteries, allowing you to work in difficult field conditions.
  • Small dimensions and weight facilitate transportation in the field.
  • Ease of installation and ease of operation.
  • Lower cost compared to devices of constant potential.
Name of the parameter Value
The amplitude of the voltage on the X-ray tube 180 kV
The value of the exposure dose

 

600 mR

it is indicated at a distance (500 ± 20) mm from the end of the X-ray unit in a straight beam for 1.5 minutes at the supply voltage of the device (230 ± 2) V for a device with a full resource

Focal spot diameter 3 mm
The method of transmission Panoramic, radiation output ~1500
The maximum time the X-ray tube is energized ≤15 min per hour
Maximum transmission thickness 15mm (D7 + Pb)
20mm (F8 + RCF)
30mm (F8 + NDT 1200)
Sensitivity of radiographic control according to GOST 7512-82 2
Degree of protection IP20
Power supply Single-phase AC 230V±10% or 220V±10% / 50Hz
Power consumption not more than 150 В·А
Operating temperature range from -400С до +500С
Overall dimensions of the X-ray unit 410 x 112 x 210 mm
Weight of the X-ray unit 5,5 kg
Overall dimensions of the control panel 310 x 260 x 150 mm
Weight of the control panel 6 kg