EcoImpulse EI-N
Cost:
On request
Description
Specifications
The EcoImpulse line of portable X-ray machines uses the principle of explosive electron emission in an X-ray tube with a cold cathode.
The main argument when choosing this equipment is the budget solution of radiographic tasks in difficult field conditions. To increase mobility, batteries are used as a power source for the X-ray machine.
The standard EcoImpulse kit includes the following components:
- X-ray unit
- high-voltage cable
- portable X-ray control panel
- cable network
- case
- 24V battery (optional)
- remote control (optional)
- housing diaphragm (optional)
It is possible to retrofit additional equipment on request.
Main features of EcoImpulse pulsed X-ray machines:
- The possibility of both directional and panoramic transmission.
- Short exposures — the only adjustable parameter of the device is the exposure time (voltage and current are unchanged).
- To obtain high-quality contrast images, it is recommended to use a highly sensitive X-ray film with amplifying screens.
- Application in areas with low intensity, the maximum operating time of the device should not exceed 15 minutes per hour.
- An autonomous source of X-ray radiation when using batteries, allowing you to work in difficult field conditions.
- Small dimensions and weight facilitate transportation in the field.
- Ease of installation and ease of operation.
- Lower cost compared to devices of constant potential.
| Name of the parameter | Value |
| The amplitude of the voltage on the X-ray tube | 300 kV |
| The value of the exposure dose | 1200 mR
it is indicated at a distance (500 ± 20) mm from the end of the X-ray unit in a straight beam for 1.5 minutes at the supply voltage of the device (230 ± 2) V for a device with a full resource |
| Focal spot diameter | 2,5 mm |
| The method of transmission | Panoramic, radiation output ~1800 |
| The maximum time the X-ray tube is energized | ≤15 min per hour |
| Maximum transmission thickness | 25 mm (D7 + Pb) 30 mm (F8 + RCF) 50 mm (F8 + NDT 1200) |
| Sensitivity of radiographic control according to GOST 7512-82 | 2 |
| Degree of protection | IP20 |
| Power supply | Single-phase AC 230V±10% or 220V±10% / 50Hz |
| Power consumption | not more than 300 V·A |
| Operating temperature range | from -400С до +500С |
| Overall dimensions of the X-ray unit | 525 x 140 x 220 mm |
| Weight of the X-ray unit | 8,1 kg |
| Overall dimensions of the control panel | 310 x 260 x 150 mm |
| Weight of the control panel | 6,3 kg |