EcoGen 450

Cost: On request
Description
Specifications

The EcoGen line of stationary X-ray devices of the cable type is designed to solve a wide range of tasks in radiography and fluoroscopy. Provide high-quality and reliable generation of X-ray radiation.

The standard EcoGen 450 kit includes the following components:

  • cathode high voltage generator
  • anode high voltage generator
  • ceramic metal X-ray tube
  • high–voltage cable – 2 pcs.
  • X-ray machine control panel
  • closed-loop oil cooling system
  • cable set

It is possible to retrofit the kit with additional equipment on request.

The main features of stationary X-ray devices of the EcoGen cable type:

  • High-quality long-term radiation, with low pulsations of high voltage and current, as well as high stability of parameters.
  • The versatility of the equipment allows it to be used not only in industry, but also in scientific laboratories.
  • The possibility of round-the-clock operation due to the safety margin of the generator in terms of power. In addition, this is facilitated by constant monitoring of the state of the device.
  • Ease of installation, which allows not only to quickly put into operation, but also to integrate into existing industrial systems.
  • Modular design of the X-ray machine.

Allows the replacement of individual components, simplifies the repair and retrofitting of the X-ray machine (for example, an additional X-ray tube, a longer high-voltage cable).

  • A library of X-ray tubes and an automated procedure for their training.
  • Maintainability. The high-voltage generator is made in the form of a single module consisting of a power module and a high-voltage unit. The high-voltage part is placed in oil, disassembled and assembled without degassing and vacuuming, which facilitates maintenance.
  • An autonomous control panel with a graphical built-in monitor. User-friendly interface in English.
  • All components of the X-ray machine pass the output test control at the factory.

EcoGen 450 high voltage generator

Output voltage 10 ÷ 450 kV
Output current 0 ÷ 45 mA
Maximum generator power 4500 W
Accuracy of setting the output voltage < ±1%
Reproducibility of output voltage ±0,01% at constant temperature
Accuracy of setting the output current ±0,1%
Reproducibility of output current ±0,01% at constant temperature
Power supply 220V/380V
Frequency 50Hz

Bipolar tubes of the EcoGen 450 X-ray machine

450-04.10 450-25.55 450-75
Maximum voltage 450kV
Focal spot size IEC336 0,15mm 1,2mm
0,4mm 3,0mm 4,5mm
Focal spot size EN12543 0,4mm 2,5mm
1,0mm 5,5mm 7,5mm
Maximum power of the tube at the anode 700W 900W
1500W 4500W 800W
Tube current at max. tube voltage 7mA 10mA
15mA 45mA 24mA
Radiation output angle 40°х30° 40°х40° 40°х40°
Type of high voltage connector R28
Weight 105kg 95kg 95kg